059/90

Recommendation Date
Recipient Name
Queenstown Airport Corp.
Text
Remove the present substantial concrete gate posts on the extended centre line of runway 05 and replace them with a light weight frangible structure to reduce the hazard to overrunning aircraft.
Reply Text
It is our intention to act upon your recommendation that the present substantial concrete gateposts on the extended centreline of Runway 05 be replaced with lightweight frangible posts to reduce the hazard to overrunning aircraft.
Related Investigation(s)